Loading Rheostat 3.5KW Bank Three Phase

Loading Rheostat 3.5KW Bank Three Phase

Product Code : SCL-EAE-11314

This loading rheostat bank is a three-phase resistive load with a capacity of 3.5 kW. With equal resistance in each phase it forms a balanced load at unity power factor. Three-phase alternators, generators and machine trainers can then be run on load while line voltage, line current and power are recorded.

Specifications of the three-phase 3.5 kW bank

ComponentSpecification
Equipment typeThree-phase resistive load bank
Load capacity3.5 kW (whether total or per phase is confirmed in the quotation)
Phase configurationThree phase
Load characteristicResistive, unity power factor when balanced
Confirmed in the quotationVoltage, frequency and current ratings
House codeSCL-EAE-11314
ManufacturerLab Exports, Delhi

Three-phase power measurements with the bank

For a balanced resistive load the total power is P = √3 × VL × IL. Here VL is the line voltage and IL the line current. Every line then carries the same current.

  • Two-wattmeter method. Put the current coils of two portable analog wattmeters in two of the lines and join their pressure coils to the third line. On a balanced resistive load the two readings come out equal, and their sum is the total power. Compare it with √3 × VL × IL.
  • Line and phase values. Measure the line voltage and the voltage across one phase with a multi range digital desk stand meter. In star the phase voltage is the line voltage divided by √3; in delta the two are equal.
  • Balance check under load. Fit an analog ammeter panel in each line. With the machine at rated speed and the load applied in steps, the three line currents should stay equal. Unequal currents point to an unbalanced load or a loose connection.

Connecting the three phases

  1. Check that the supply voltage, frequency and current suit the load rating of the bank.
  2. With the source isolated, verify the phase sequence and connect the three phases through the meters.
  3. Run the alternator or machine to rated conditions at no load and note the readings.
  4. Apply the load in steps at constant speed, recording line voltage, line current and power each time.

Frequently Asked Questions

How is a three-phase resistive load bank designed?

It usually has three equal sets of resistance elements, one per phase, joined in star or delta. Keeping the three sets equal gives a balanced load. For this bank, the voltage, current and whether 3.5 kW is total or per phase are confirmed in the quotation.

What is a balanced load in a three-phase circuit?

A balanced load has the same impedance in each of the three phases. On a balanced supply its three line currents are equal in size and spaced evenly in phase, so the neutral of a star connection carries no current.

How does the power change if the same resistors are joined in star instead of delta?

It falls to one third. In star each resistor gets the line voltage divided by √3, and power in a resistor goes with the square of its voltage. The same set of resistors in delta takes three times the star power.

What is the phase sequence of a three-phase supply, and why check it?

Phase sequence is the order in which the three phase voltages reach their peaks. It decides the direction a three-phase motor runs, and it must match before machines are paralleled.

Other loads for machine tests and power factor work

More apparatus is in the Electrical and Electronics section of the Physics Lab range.

To enquire, email [email protected] with the house code SCL-EAE-11314 and the quantity, or use the Add To Cart button on this page.

Last updated: 23 November 2026

   

Office Address

Works:11/315, Lalita Park, Laxmi Nagar, Delhi, 110092

[email protected]

Follow Us