Lamp Load 2.5KW
Product Code : SCL-EAE-11304
This lamp load is a lamp-based resistive load with a total capacity of 2.5 kW. Connected to a generator, alternator or power supply, its lamps draw power and glow. The class sees at a glance that load is applied while voltage, current, power and voltage regulation are measured.
Specifications of the 2.5 kW lamp load
| Component | Specification |
|---|---|
| Load type | Lamp-based resistive load |
| Total load capacity | 2.5 kW |
| Load indication | Lamps glow while the load draws power |
| Sources it can load | Generators, alternators and power supplies within its rating |
| Operating voltage, phase, number and rating of lamps, switching arrangement | Confirmed in the quotation |
| House code | SCL-EAE-11304 |
| Manufacturer | Lab Exports, Delhi |
Generator and alternator tests with the lamp load
Once hot, a filament lamp behaves almost as a plain resistance. Its current is nearly in phase with the voltage. The power taken is then close to V × I, the product of the lamp voltage and the lamp current.
- Voltage regulation of an alternator. Run the alternator at rated speed and note the no-load terminal voltage on a digital LCD voltmeter. Apply the lamp load in stages and read the load current on a digital LCD ammeter. Regulation = (no-load voltage - full-load voltage)/full-load voltage × 100 percent.
- Steady speed. An analog frequency meter on the alternator output shows whether the speed has held steady between readings, because the frequency of an alternator depends on its speed.
- External characteristic. Record terminal voltage and load current at each lamp step and plot one against the other. The curve shows how far the output voltage of the machine sags as the load grows.
- Reading the lamps. The lamps glow less brightly when the terminal voltage sags under load. This gives a quick visual check alongside the meter readings.
Before switching on the lamps
- Check that the source voltage, frequency and phase suit the rating of the lamp load.
- Stand the unit on a firm surface with space around it, because the lamps give off heat as well as light.
- Make all connections through the meters with the source switched off.
- Bring the source to rated conditions first, then add load gradually and note the readings at each step.
Documentation and supply
Most Lab Exports products carry a one-year manufacturer warranty.
Lab Exports manufactures the 2.5 kW lamp load at its works in Laxmi Nagar, Delhi, and supplies it to engineering colleges, polytechnics and technical institutes in India and 60+ countries, handling the export documents for each shipment. More about the company is on the About Lab Exports page.
Frequently Asked Questions
What is a lamp load bank used for?
It puts a visible resistive load on a source under test. On this 2.5 kW unit the lamps glow as power is drawn. Students watch the load rise while they measure the voltage, current, power and regulation of a generator, alternator or power supply.
What does lamp load mean?
It means an electrical load made up of lamps. A filament lamp draws a much higher current for a moment at switch-on, while the filament is still cold. Switches are therefore often given a separate rating for lamp loads.
What happens to the total resistance when more lamps are switched on?
It falls. Each lamp switched in parallel adds another path for current, so the combined resistance drops, the current rises and the source carries more load. That is why the load grows as lamps are added.
Other loads for generator and alternator tests
More apparatus is in the Electrical and Electronics section of the Physics Lab range.
To enquire, email [email protected] with the house code SCL-EAE-11304 and the quantity, or use the Add To Cart button on this page.
Last updated: 23 November 2026