Reversing Key / Commutator

Reversing Key / Commutator

Product Code : SCL-EAE-11286

This reversing key, or commutator, is a single circuit-reversing switch unit. Moving its operating contact from one position to the other crosses the connections to the load. Current then flows the opposite way through a coil, meter or galvanometer, and no lead has to be moved.

Specifications of the reversing key

ComponentSpecification
UnitOne circuit-reversing switch unit
Primary functionReversing circuit polarity and current direction
OperationOperating contact moved between two positions
Supplied1 × Reversing Key / Commutator
Contact material, terminal layout and ratingsConfirmed with the quotation
House codeSCL-EAE-11286
ManufacturerLab Exports, Delhi

Reversing the current in practical work

The key sits between the supply and the part of the circuit under study. One pair of its connections goes to the supply and the other pair to the load.

  • Tangent galvanometer. Join a battery eliminator, a rheostat, an ammeter and the key to the coil of a tangent galvanometer. Read both ends of the pointer, move the key to reverse the current, and read both ends again. The mean of the four readings is used.
  • Direction of a meter deflection. Connect a galvanometer, a cell and a high resistance in series through the key. Note which way the needle moves, then reverse the key. The needle swings to the other side, showing that the deflection follows the direction of current.

Before taking readings

  1. Place the commutator on a clean, dry, stable bench.
  2. Identify the supply terminals and the load terminals before connecting.
  3. With the power off, wire the low-voltage supply to the supply side and the coil, meter or galvanometer to the load side.
  4. Switch on, note the reading, then move the operating contact and note the reversed reading.

Frequently Asked Questions

What is the purpose of a commutator?

In the physics lab, a commutator or reversing key changes the direction of current in part of a circuit without moving any leads. In a DC motor the same word means a split ring on the shaft, which is a different part with a different job.

Does a reversing key have four terminals or six?

Designs differ, so check the markings before wiring. Whatever the count, one set of terminals takes the supply and another set takes the coil, meter or galvanometer. The terminal layout of this unit is confirmed with the quotation.

In the tangent galvanometer experiment, why do we reverse the current and read the deflection again?

Reversing the current and averaging the readings cancels small errors. These include a coil not set exactly in the magnetic meridian and a pointer not exactly at zero. The mean deflection for both directions is then used in the calculation.

What is the function of the reversing key in a tangent galvanometer circuit?

It lets the current through the coil be reversed while its size stays the same. The rheostat and ammeter are left untouched, so the two deflections for one current can be compared directly.

Other apparatus used with the reversing key

More apparatus is in the Electrical and Electronics section of the Physics Lab range.

To enquire, email [email protected] with the house code SCL-EAE-11286 and the quantity, or use the Add To Cart button on this page.

Last updated: 23 November 2026

   

Office Address

Works:11/315, Lalita Park, Laxmi Nagar, Delhi, 110092

[email protected]

Follow Us