Laboratory Equipment Manufacturer, Suppliers and Exporter in India

Lab Exports is leading Laboratory Equipment Manufacturer,and supplier and Exporter in India,

The Laboratory Equipment range holds the general items that school, college, university and research labs share across subjects. It covers sterilising, heating, weighing, mixing and separating, with autoclaves, burners, heating mantles, hot plates, water baths, balances, stirrers and centrifuges. A group of laboratory instruments adds analysers, an incubator, fume cupboards and safety items. Retort clamps and bossheads hold glassware on stands during heating, distillation and titration.

Groups in the general laboratory equipment range

A full item list sits on each group page. Below, each row sums up one group and links one product to start from.

Sub-categoryWhat it holdsExample product
AutoclavesElectric, gas and stainless steel autoclaves, a portable single drum unit and a draining basketClassic Standard Autoclave
BurnersBunsen burners in several forms, Tirrill, Teclu and Meker burners, natural gas and high temperature burners, an electric burner, alcohol lamps, a block heater, a flame spreader, burner tubing and lightersAdjustable Bunsen Burner
Heating MantleMantles for round-bottom flasks, digital mantles, a multi position mantle and mantles with a built-in stirrerHeating Mantle With Stirrer (Rota Mantle)
Hot PlatesRound, rectangular, digital, ceramic and general purpose hot plates, and hotplate magnetic stirrersHotplate & Magnetic Stirrer
CentrifugesClinical, swing out head, high speed, micro, mini, universal, hand and haematocrit centrifuges, and a fixed angle rotorCentrifuge, High Speed
BalancesAnalytical, precision, compact, portable and high range electronic balances, triple-beam, physical, chemical, Roberval and Beranger balances, mass sets, slotted mass hangers and an anti-vibration tableTriple-Beam Balance
Laboratory StirrerMagnetic stirrers, including mini and motorless types, hot plate magnetic stirrers, a vortex mixer and magnetic stirrer barsVortex Mixer
Laboratory InstrumentsA UV-VIS spectrophotometer, a photo colorimeter, melting point apparatus, moisture analysers, a Karl Fischer titrimeter, an incubator, an oven, fume cupboards, a biosafety cabinet, vacuum pumps, a shaker, safety goggles and bench accessoriesSingle Beam Microprocessor UV-VIS Spectrophotometer
Water BathUnstirred thermostatic, stirred, digital, triple and serological water baths, heated ultrasonic baths, and a lid, a test tube rack, bath spheres and a water bath kit for hotplatesDigital Serological Water Bath
Retort ClampRetort clamps with cork or rubber jaws, with or without a bosshead, three and four prong clamps, stainless steel clamps and three finger clamps with shaftRetort Clamp with Bosshead, Rubber Jaws
BossheadStandard, swivel, cross, squared, hook, three angle and frame bossheads in stainless steel, chromium plated malleable cast iron or aluminium, and a safety screwThree Angle Bosshead

What to settle before ordering general lab equipment

  • List the work first. Write down each test, practical and sample size, then match an item to it. For weighing, the smallest sample and the full load with its container decide between an analytical and a precision balance.
  • Match the heater to the glassware. A mantle such as the Heating Mantle 1000ml takes a round-bottom flask of its size. Flat-bottomed beakers and conical flasks go on a hot plate, and a water bath gives gentle, even heat up to the boiling point of water.
  • Check the room. Allow bench space and mains points, a gas supply for gas burners and the Gas Autoclave, and ventilation for work that gives off fumes. A firm, level bench away from draughts, or the Balance Anti-Vibration Table, suits fine weighing.
  • Size sterilisers to the load, and choose electric or gas heating to suit the lab.
  • Plan accessories and spares with the main items: Magnetic Stirrer Bar sets, Burner Tubing, a water bath rack and lid, mass sets and a centrifuge rotor.
  • Include safety items in the same list, such as Safety Goggles and a Safety Screen. Name every item in an enquiry or tender by the house code on its product page.

Practical work these items support

Heating practicals begin with the Bunsen burner. With the air hole closed it gives a yellow, luminous flame. With the air hole open it gives the hotter, blue, non-luminous flame used for heating. Bunsen Burners in this range suit school chemistry and biology benches.

For distillation and reflux, a round-bottom flask sits in a mantle while a Retort Clamp with Bosshead, Cork Jaws holds its neck on the stand. Titrations use a clamp to hold the burette upright over the flask. A Magnetic Stirrer keeps the flask contents mixed.

Weighing practicals run from the Physical Balance and its mass set in school to the Balance, Analytical used to weigh solids for standard solutions. In microbiology, students sterilise media in an autoclave, incubate plates, and count colonies on the Digital Colony Counter. A colorimeter finds the concentration of a coloured solution from how much light it absorbs.

Frequently Asked Questions

Which type of balance is used in a laboratory?

Most labs use an analytical balance for small samples and a precision balance for larger loads. Analytical balances read to a fraction of a milligram and have a draft shield. Precision, or top-loading, balances take heavier loads on wider pans at coarser readability. Choose by the smallest sample, the full load with its container, and how steady the bench is. Teaching labs also use beam balances.

What is the use of a water bath in a laboratory?

A water bath holds samples at a steady, even temperature up to the boiling point of water. Labs use it to incubate samples, warm reagents, thaw frozen material and heat flammable liquids without a flame or hot plate surface. Fill it with distilled water to limit scale, and keep the level above the heater.

What are the key considerations when choosing an autoclave?

Start with the load: liquids, media and glassware, or wrapped and hollow items. Size the chamber to fit the tallest bottles and widest racks, with space around the lid. Check the heat source, power or gas supply and water needs, and use distilled water. Look for a pressure safety valve and a secure lid.

Which source of heat is commonly used in the laboratory?

The Bunsen burner is the most common heat source in school and college labs. Where an open flame is unsafe, such as near flammable solvents, labs use electric heaters instead. Hot plates take flat-bottomed vessels, heating mantles take round-bottom flasks and water baths give gentle heat.

What are the safety precautions for a Bunsen burner?

Wear goggles, tie back long hair and clear papers from the bench. Check the tubing for cracks, close the air hole, and hold the lit match or lighter over the barrel before turning on the gas. Never reach over the flame or leave it alone, and turn the gas off at the tap.

What is the function of a retort stand with a clamp?

It holds glassware firmly at the height and angle the experiment needs, so both hands stay free. The heavy base keeps the stand from tipping. A bosshead locks the clamp to the rod, and the clamp grips a burette, flask, condenser or test tube during titration, distillation, filtration or heating.

To enquire, email [email protected] with the house codes and quantities of the items you need. Tender buyers can also see the Tenders and OEM page.

Last updated: 24 November 2026

There are no products in the category

Office Address

Works:11/315, Lalita Park, Laxmi Nagar, Delhi, 110092

[email protected]

Follow Us