Copper Voltameter
Product Code : SCL-EAE-11125
The copper voltameter is an electrolysis apparatus for verifying Faraday's first law and finding the electrochemical equivalent (ECE) of copper. Three parallel copper plates stand in a 250 ml glass jar under an insulating lid. A measured direct current passes through a copper-salt electrolyte from the two outer plates, the anodes, to the removable centre plate, the cathode. The gain in mass of the cathode is set against the charge passed.
Specifications of the copper voltameter
| Component | Specification |
|---|---|
| Parts | Glass jar, insulating lid, three copper plates and terminals |
| Jar | Glass, 250 ml |
| Copper plates | Three, parallel, each about 75 × 25 × 1 mm |
| Electrodes | The two outer plates are joined as anodes; the removable centre plate is the cathode for weighing |
| Needed separately | Current source, measuring leads, balance and a copper-salt electrolyte (copper sulphate solution is the usual one) |
| Principle | Electrolysis, Faraday's laws of electrolysis |
| Measured relationship | Electric charge passed against mass of copper deposited |
| Main result | Electrochemical equivalent of copper |
| House code | SCL-EAE-11125 |
| Manufacturer | Lab Exports, Delhi |
Finding the ECE of copper and related tasks
By Faraday's first law, the mass m deposited at an electrode is proportional to the charge passed, so m = ZIt. Here I is the current in amperes, t the time in seconds and Z the electrochemical equivalent in kg per coulomb.
- ECE of copper. Weigh the clean, dry centre plate, the cathode, on a precision balance. Fill the jar with copper sulphate solution and fit the lid with the three plates. Join the voltameter in series with a DC supply such as a battery eliminator, a rheostat, an ammeter and a one-way plug key. The centre plate goes to the negative terminal, and the two outer plates, joined together, to the positive. Pass a steady current for a time measured on an analog stop clock. Then lift out the centre plate, rinse it, dry it and weigh it again. Z = m/(It).
- Checking the first law. Repeat the run with the same current for different times, or with different currents for the same time. A graph of mass deposited against charge It is a straight line through the origin, and its slope is Z.
- Reduction factor of a tangent galvanometer. Put a tangent galvanometer in series with the voltameter and note its steady deflection θ. The current found from the copper deposit, I = m/(Zt), then gives the reduction factor K, since I = K tan θ.
Getting a clean copper deposit
- Clean and dry the centre plate before the first weighing. With an anode on each side, copper deposits on both of its faces.
- Keep the current moderate and steady with the rheostat. Too high a current density gives a loose, dark deposit that can flake off before weighing.
- After the run, rinse the cathode gently so the deposit is not washed away, and dry it fully before weighing.
Frequently Asked Questions
What does a copper voltameter determine?
It determines the electrochemical equivalent of copper, the mass of copper deposited by one coulomb of charge. The value is found from Z = m/(It) and is about 3.29 × 10-7 kg per coulomb, or 0.000329 g per coulomb.
Does copper sulphate solution conduct electricity?
Yes. In water, copper sulphate splits into copper ions and sulphate ions, and these ions carry the current through the solution. That is why it serves as the electrolyte. At the cathode, copper ions take up electrons and deposit as copper metal.
Which process is used to purify copper?
Electrolytic refining, which works like this voltameter. Impure copper is made the anode and a thin sheet of pure copper the cathode, in copper sulphate solution. Copper dissolves from the anode and pure copper deposits on the cathode, while impurities settle below the anode.
Why should the cathode plate not be touched with the fingers?
Grease and dirt from the fingers stop copper depositing evenly, so the deposit may be patchy or loose. Handle the cleaned cathode by its edges and dry it before each weighing, so that only copper adds to its mass.
Other apparatus for electrolysis practicals
More apparatus is in the Electrical and Electronics section of the Physics Lab range.
To enquire, email [email protected] with the house code SCL-EAE-11125 and the quantity, or use the Add To Cart button on this page.
Last updated: 23 November 2026