Loading Rheostat 3.5KW Bank

Loading Rheostat 3.5KW Bank

Product Code : SCL-EAE-11315

This 3.5 kW loading rheostat bank works as an adjustable resistive load. Varying its effective resistance, continuously or in steps depending on design, changes the current drawn from a motor-generator set, power supply or training panel. Students measure voltage, current, real power and regulation under changing load.

Specifications of the 3.5 kW loading rheostat bank

ComponentSpecification
Equipment typeAdjustable resistive-load bank
Rated loading capacity3.5 kW
Load characteristicResistive
AdjustmentLoad-adjustment control or selection mechanism, continuous or stepped depending on design
ConnectionsElectrical connection terminals
Confirmed in the quotationResistance range, voltage rating, maximum current, cooling and duty cycle
House codeSCL-EAE-11315
ManufacturerLab Exports, Delhi

Planning a load test within the 3.5 kW rating

On a DC or single-phase source the power drawn is P = V × I, and it must stay within 3.5 kW. So a source at voltage V, loaded to the full rating, gives I = 3500/V amperes. That current must also be within the current rating of the bank and of the machine.

  • Rating check on paper. Before wiring, note the source voltage on a digital multimeter and the rated current on the machine plate. Work out the full-rating current of the bank for that voltage, and note its current rating. The smallest of the three currents sets the highest load step for the run.
  • Stepping up to the limit. Start at maximum resistance. Raise the load step by step, reading current on a digital LED ammeter and voltage on a digital LED voltmeter. Work out V × I at each step and stop before either the current limit or 3.5 kW is reached.

Documentation and supply

Most Lab Exports products carry a one-year manufacturer warranty.

Lab Exports manufactures the 3.5 kW loading rheostat bank at its works in Laxmi Nagar, Delhi, and supplies it to engineering colleges, polytechnics and technical institutes in India and 60+ countries, handling the export documents for each shipment. More about the company is on the About Lab Exports page.

Frequently Asked Questions

How do you choose the right load bank for a test?

Match the power rating, voltage, current, type of load, duty and control to the test. This bank is a resistive load of 3.5 kW with continuous or stepped adjustment. Its resistance range, voltage, current, cooling and duty cycle are confirmed in the quotation.

What is the danger of connecting a rheostat in parallel with the supply?

Across the supply, a rheostat turned to a very low resistance acts almost like a short circuit, and the current can rise far above its rating. That is why a loading rheostat is connected at maximum resistance and the load is raised gradually.

Does a rheostat control current?

Yes. In series with a circuit it limits the current. Used as a load across a source, as with this bank, a lower resistance setting draws more current, since I = V/R for a source holding its voltage V.

Other loads for motor, generator and supply tests

More apparatus is in the Electrical and Electronics section of the Physics Lab range.

To enquire, email [email protected] with the house code SCL-EAE-11315 and the quantity, or use the Add To Cart button on this page.

Last updated: 23 November 2026

   

Office Address

Works:11/315, Lalita Park, Laxmi Nagar, Delhi, 110092

[email protected]

Follow Us