Vernier Caliper IME Type

Vernier Caliper IME Type

Product Code : SCL-AM-11188

This IME-type vernier caliper, also written vernier calliper, measures outside and inside diameters, depths and steps up to 150 mm or 6 inches. The body is hardened carbon steel, chrome-plated, with laser-engraved metric and imperial scales. Metric readings go to 0.02 mm. A spring-tensioned thumb wheel moves the slide, a locking screw holds the reading, and the caliper is stored in a velvet-lined case.

Specifications of the IME-type vernier caliper

ComponentSpecification
Range0 to 150 mm and 0 to 6 inches, dual scale
Least count, metric0.02 mm
Least count, imperial1/128 inch
BodyHardened carbon steel, chrome-plated
GraduationsLaser-engraved
Slide adjustmentThumb wheel with spring tension
Slide lockLocking screw on the sliding head
MeasurementsOutside and inside jaws and a depth rod, for outside, inside, depth and step readings
Supplied withVelvet-lined protective case and a user instruction guide with basic calibration and zero-error adjustment steps
House codeSCL-AM-11188
ManufacturerLab Exports, Delhi

Measuring tasks with the vernier caliper

The least count is the value of one main scale division divided by the number of vernier divisions. On this caliper the main scale is in 1 mm divisions and the least count is 0.02 mm. The least count is the smallest step the vernier shows; it is not the same thing as the accuracy of the caliper. The outside jaws take external sizes, the inside jaws take bores, and the depth rod reads depths.

  • Volume and density of a solid. Measure the diameter d of a metal cylinder at several points and its length L with the outside jaws. Its volume is πd2L/4. Find its mass on a physical balance, then divide mass by volume to get the density.
  • Radius of a pendulum bob. Measure the diameter of a bob from the pendulum bobs or spheres set in two directions at right angles, and take the mean. Half of it is the radius r. The length of a simple pendulum is taken to the centre of the bob, so r is added to the thread length.
  • Wall thickness and depth of a hollow vessel. For a beaker or tumbler, read the external diameter with the outside jaws and the internal diameter with the inside jaws. The wall thickness is half their difference. Then stand the beam on the rim and use the depth rod to read the inside depth.

Reading the scales and correcting zero error

  1. Close the jaws fully and check whether the vernier zero lines up with the main scale zero. Note any zero error and its sign.
  2. Open the jaws with the thumb wheel, place the object between them and close them gently without forcing.
  3. Tighten the locking screw so that the slide cannot shift while the scales are read.
  4. Take the main scale reading just before the vernier zero. Add the number of the coinciding vernier line multiplied by the least count.
  5. Subtract the zero error to get the true reading. Repeat at other positions on the object and take the mean.

Frequently Asked Questions

What does IME type mean on this vernier caliper?

IME Type is the model name of this caliper, and the initials have no standard expansion. On this model a thumb wheel with spring tension moves the sliding jaw in fine steps. A locking screw on the sliding head then holds the jaw once it touches the object.

How many scales does this caliper have?

It has two main scales, one in millimetres from 0 to 150 mm and one in inches from 0 to 6 inches, each with its own vernier. The metric vernier reads to 0.02 mm. The inch vernier reads to 1/128 inch.

Which is larger, a main scale division or a vernier scale division?

The main scale division is larger. Each vernier division is made shorter than a main scale division by exactly the least count. That small difference is what lets the coinciding line show fractions of a millimetre.

How is a positive or negative zero error recognised?

Close the jaws fully and look at the vernier zero. If it lies to the right of the main scale zero, the zero error is positive. If it lies to the left, the error is negative. Subtract the error, with its sign, from every observed reading.

Why should a diameter be measured at several places?

A cylinder or sphere is rarely perfectly round and uniform. Readings at different points along its length, and in two directions at right angles, show any variation. Their mean gives a more reliable diameter than a single reading.

Other items for measurement and density practicals

More apparatus is in the Applied Mechanics section of the Physics Lab range.

To enquire, email [email protected] with the house code SCL-AM-11188 and the quantity, or use the Add To Cart button on this page. Tender buyers can also see the Tenders and OEM page.

Last updated: 23 November 2026

   

Office Address

Works:11/315, Lalita Park, Laxmi Nagar, Delhi, 110092

[email protected]

Follow Us