Loading Capacitor 3KVAR Bank
Product Code : SCL-EAE-11316
This loading capacitor bank provides 3 kVAR of capacitive reactive load at its rated voltage and frequency. In an AC circuit its current runs ahead of the voltage. In the lab it is used to measure reactive power and capacitance, to load an alternator with current ahead of the voltage, and to offset lagging reactive power.
Specifications of the 3 kVAR capacitor bank
| Component | Specification |
|---|---|
| Load type | Capacitive reactive load |
| Reactive-power capacity | 3 kVAR, at the rated voltage and frequency |
| Supplied | One Loading Capacitor 3KVAR Bank |
| Confirmed in the quotation | Voltage, frequency, phase, capacitance, connection method, load steps and discharge arrangement |
| House code | SCL-EAE-11316 |
| Manufacturer | Lab Exports, Delhi |
Measurements on the 3 kVAR bank
A capacitor opposes AC by its capacitive reactance, XC = 1/(2πfC), where f is the supply frequency and C the capacitance. The reactive power it supplies is Q = V2/XC = 2πfCV2, where V is the applied voltage. In an ideal capacitor the current is 90° ahead of the voltage.
- Output and capacitance from two meters. Connect the bank to its rated supply with an analog ammeter panel in the line and an analog voltmeter panel across it. Read the frequency on an analog frequency meter. On a single-phase connection, Q is nearly equal to V × I, XC = V/I and C = I/(2πfV).
- Reactive power and voltage. If an adjustable AC supply is available, repeat the readings at a few voltages below rated. Plot Q against V2: the straight line shows that the 3 kVAR figure holds only at rated voltage.
- Alternator on capacitive load. Run an alternator within its rating at rated speed and record its no-load voltage. Switch in the bank and watch the terminal voltage rise above that value, keeping it within the rated voltage of the bank. Compare this with the fall seen on a resistive load such as the Lamp Load 2.5KW.
Handling the capacitor bank
- Check that the supply voltage, frequency and phase suit the reactive-power rating of the bank.
- Place the bank in a dry, stable, ventilated area and isolate the supply.
- Inspect earthing, terminals, cables and switching before connecting.
- After switching off, let the capacitors discharge before touching any terminal.
Documentation and supply
Most Lab Exports products carry a one-year manufacturer warranty.
Lab Exports manufactures the 3 kVAR loading capacitor bank at its works in Laxmi Nagar, Delhi, and supplies it to engineering colleges, polytechnics and technical institutes in India and 60+ countries, handling the export documents for each shipment. More about the company is on the About Lab Exports page.
Frequently Asked Questions
Why is a capacitor bank rated in kVAR on its name plate?
Because its power is reactive, not real. A capacitor stores energy and returns it to the supply every cycle and uses almost no watts. Its duty is therefore stated as reactive power at rated voltage and frequency, here 3 kVAR.
Can a capacitor rated for a higher voltage be used on a lower supply?
It can, but its output drops. Reactive power goes with the square of the voltage, so below rated voltage the bank gives less than 3 kVAR. Check the rated voltage in the quotation against your supply.
Why does an alternator voltage rise with a capacitive load?
Current ahead of the voltage sets up an armature reaction that aids the main field. The leakage reactance drop also adds to the induced emf. The terminal voltage can then exceed the no-load value, so the regulation is negative.
What happens to capacitance when the voltage is increased?
For an ideal capacitor it stays the same, since capacitance depends on plate area, plate gap and dielectric. What rises is the stored charge and the reactive power, which grows with the square of the voltage. Never run the bank above its rated voltage.