Loading Rheostat 10KW
Product Code : SCL-EAE-11318
A 10 kW capacity puts this high-power resistive loading rheostat in the class needed to load a machine to several kilowatts. It takes real power from a generator or alternator and gives it off as heat. With it, a small alternator can be tested by direct loading, while students record terminal voltage, load current and output power from no load upwards.
Specifications of the 10 kW loading rheostat
| Component | Specification |
|---|---|
| Equipment type | High-power resistive loading rheostat |
| Load capacity | 10 kW |
| Load type | Resistive: real power is absorbed and given off as heat |
| Use | Loading generators and alternators for load characteristic, regulation, output power and efficiency tests |
| Supplied | One Loading Rheostat 10KW |
| Voltage, current, phase, resistance range, adjustment method, duty cycle, cooling | Confirmed in the technical quotation; check them before connection |
| House code | SCL-EAE-11318 |
| Manufacturer | Lab Exports, Delhi |
Direct load tests on a small alternator
In the direct loading method the alternator itself carries a real load, so no equivalent circuit has to be assumed. The prime mover holds the speed, and so the frequency, steady. The field excitation is set for rated voltage at no load and then left alone while the rheostat adds load.
- Regulation at unity power factor, read directly. Leave the field current at its no-load setting and load the alternator in steps up to its own full-load current. An analog panel voltmeter gives the terminal voltage V and an analog panel ammeter the load current. Regulation = (E0 - V)/V × 100 percent, where E0 is the no-load voltage and V the full-load voltage.
- Output power and efficiency. On a single-phase connection, a portable analog wattmeter in the load circuit gives the output power at each step. Divide it by the measured input to the alternator to get its efficiency, and plot efficiency against output.
Before connecting the 10 kW rheostat
- Check from the technical quotation that its voltage, current, phase, resistance and duty-cycle ratings suit the machine under test.
- Stand it in a dry, stable place with room for air to move round it, since all the power it takes leaves as heat.
- With the supply isolated, run the leads from the machine to the rheostat by way of the meters.
- With no load connected, bring the machine up to its rated speed and voltage. Raise the load one step at a time and read every meter at each step.
Frequently Asked Questions
What is a resistive-reactive (combined) load bank?
It is a load bank that joins resistive steps with inductive or capacitive steps, so a source can be tested at a power factor other than unity. This 10 kW rheostat is resistive only. To load a machine with current behind or ahead of the voltage, it is used together with a separate inductive or capacitive load of suitable rating.
Why is the direct loading test used only for small alternators?
Because the test needs a load as large as the machine rating, and all that power is turned into heat. For large alternators such a load is hard to arrange, so their regulation is found by indirect methods such as the synchronous impedance method. A machine with a full-load output within 10 kW can be loaded directly with this rheostat, provided its voltage and current ratings also match.
Why is the field excitation kept constant during the alternator load test?
Regulation describes how the terminal voltage changes with load at a fixed field current and speed. If the excitation were changed during the run, part of the voltage change would come from the field and not from the load. Set it once for rated voltage at no load, then leave it.
Other loads for alternator and generator tests
More apparatus is in the Electrical and Electronics section of the Physics Lab range.
To enquire, email [email protected] with the house code SCL-EAE-11318 and the quantity, or use the Add To Cart button on this page.