Lamps in Parallel Kit

Product Code : SCL-EAE-11194

This baseboard circuit wires three MES lamp holders in parallel, each branch with its own switch, beside an on-board 0 to 6 V DC moving-coil voltmeter. Printed wiring paths show each current path. The 3 V version has 3.5 V, 0.20 A lamps and runs on two D cells; a 6 V version uses 6 V lamps. It shows that every parallel branch receives the same voltage.

Specifications of the lamps in parallel kit

ComponentSpecification
Circuit3 lamp branches in parallel, one switch per branch
Lamp holdersMiniature Edison Screw (MES, E10) with copper contacts
LampsThree E10 (MES) lamps, 3.5 V, 0.20 A; 6 V lamps on the 6 V version
VoltmeterAnalogue moving-coil, 0 to 6 V DC, mounted on the board
Operating voltage3 V DC from two 1.5 V D cells in series, for the 3.5 V lamps; 6 V DC on the 6 V version
LoadAll three branches together draw 0.60 A and take 2.1 W at the rated lamp voltage
BaseNon-conductive polymer (Bakelite) board, 290 x 150 x 50 mm, with printed wiring paths
WeightAbout 450 g
Supplied withBoard with built-in voltmeter, 3 MES bulbs, 3 pre-wired switches, battery holder for two D cells, 4 connecting leads (banana plug to crocodile clip) and a student experiment guide
House codeSCL-EAE-11194
ManufacturerLab Exports, Delhi

Parallel circuit activities on the kit

Fit the three MES bulbs and connect the battery holder with two D cells, or a battery eliminator set to 3 V for the 3.5 V lamps. Use 6 V only with the 6 V version and its 6 V lamps. Each lamp is then connected directly across the supply.

  • Same voltage on every branch. Close one branch switch and read the voltmeter. Close the second and third switches in turn. The reading stays practically the same and the lamps glow equally.
  • Branch currents add up. Put an ammeter in one supply lead and note how the total current rises as each branch is switched on, so that I = I1 + I2 + I3. At the rated 3.5 V each lamp takes 0.20 A, so all three together take 0.60 A. On two D cells each current is a little lower.
  • Independent loads. Open any one switch, or unscrew one bulb. The other lamps stay lit at the same brightness.
  • Parallel against series. Repeat with the Lamps in Series Kit, where each added lamp makes all of them dimmer. The difference explains why house wiring, studied on the Domestic Circuit Apparatus, connects appliances in parallel.

Frequently Asked Questions

What is the role of the voltmeter on the board?

It reads the voltage across the lamp branches, on a 0 to 6 V DC scale. As each branch switch is closed the reading stays practically the same, which shows that every parallel branch gets the same voltage.

Is the kit suitable for school labs?

Yes. The 3 V version runs on two 1.5 V D cells, on a non-conductive Bakelite board, and all three lamps together take at most 2.1 W. Three 3.5 V MES bulbs, a battery holder and four connecting leads come with it.

What happens when one bulb is removed from a parallel circuit?

The other lamps stay lit at the same brightness. Each lamp has its own path across the supply, so breaking one branch leaves the others unchanged and only the total current falls. Opening a branch switch on this kit shows the same thing.

Why do bulbs glow brighter in parallel than in series?

In parallel each bulb gets the full supply voltage, so it draws its full current and glows normally. In series the supply voltage is shared between the bulbs, so each one gets only part of it and glows dimmer.

Why is household wiring done in parallel?

So that every appliance gets the full mains voltage and can be switched on or off without affecting the others. A broken lamp or a switched-off heater does not cut the rest. The kit shows the same idea safely at low voltage with three switched lamps.

Other apparatus for school electricity lessons

More apparatus is in the Electrical and Electronics section of the Physics Lab range.

To enquire, email [email protected] with the house code SCL-EAE-11194 and the quantity, or use the Add To Cart button on this page.

Last updated: 23 November 2026

   

Office Address

Works:11/315, Lalita Park, Laxmi Nagar, Delhi, 110092

[email protected]

Follow Us