7 Decade Resistance Box
Product Code : SCL-EAE-11296
This resistance box has seven decades, each holding resistors of one power of ten, ten times the value of the decade below. The settings of all seven add together, and each decade gives one place value of the total. One box supplies a known resistance for substitution, bridge, meter-checking and circuit-law work.
Specifications of the 7 decade resistance box
| Component | Specification |
|---|---|
| Instrument type | Variable resistance decade box |
| Number of decades | 7 |
| Decade values | Each decade ten times the value of the one below |
| Selection principle | Additive: the settings of all decades sum to the total resistance |
| Markings | Decade markings for reading the total |
| Span, smallest step, tolerance and power rating | Confirmed with the quotation |
| House code | SCL-EAE-11296 |
| Manufacturer | Lab Exports, Delhi |
Measurements that use a dialled-in resistance
The control on each decade sets how many of its steps are in circuit. Seven decades give a wide choice of values from one instrument, in place of a drawer of loose fixed resistors.
- Substitution method. Put an unknown resistance coil in a circuit and read the current on an ammeter. Swap in the decade box and adjust its decades until the same current flows again. The value set on the box is then the unknown resistance.
- Known arm of a bridge. Wired into a meter bridge, the decade box supplies the known resistance R and a galvanometer shows the null. Adjust the decades so that balance comes near the centre of the wire.
- Circuit laws. Set different values on the box in Ohm's law and Kirchhoff's law circuits, and use it as a variable load when checking a meter against a standard.
Connecting and adjusting the decade box
- Switch off and isolate the circuit before making connections.
- Set the decades to a starting value high enough to keep the current small.
- Connect the resistance terminals into the circuit with suitable leads.
- Switch on and adjust the decades from the highest order downwards until the required reading or balance is reached.
Frequently Asked Questions
How should a decade resistance box be chosen for a lab?
Start with the span and the smallest step the work needs. In a decade box the lowest decade sets the smallest step, and the highest decade sets the size of the top values. Then check the tolerance and power rating. For this seven-decade box, those figures are confirmed with the quotation.
Can a decade box be set to zero ohms?
Not exactly. With every decade at its lowest setting, the internal wiring, contacts and terminals still leave a small residual resistance. Allow for it when the box is used for very low values.
Why are the decades of the box connected in series?
So that their resistances add. Each decade contributes the value set on it, so the box presents the sum of all seven at its terminals. This is why the settings read like the digits of the total.
Dial, plug, substitution and electronic resistance boxes
- Decade Resistance Box, Dial Type
- Resistance Box Plug Type
- Resistance Substitution Box
- Resistance Box Electronic Type
More apparatus is in the Electrical and Electronics section of the Physics Lab range.
To enquire, email [email protected] with the house code SCL-EAE-11296 and the quantity, or use the Add To Cart button on this page.
Last updated: 23 November 2026