Four Way Plug Key

Four Way Plug Key

Product Code : SCL-EAE-11285

This four way plug key is a manual plug switch with a four-way contact arrangement on one base. A plug placed in the chosen position completes that path. Cells, resistances or branches can then be selected in turn without pulling leads off between readings.

Specifications of the four way plug key

ComponentSpecification
Device typeManual multi-way laboratory plug switch
ConfigurationFour way
Primary functionMaking, breaking or selecting electrical circuit paths
Supplied partsBase assembly with four-way contact arrangement and electrical connection terminals
Selector plugsNumber confirmed with the quotation; state the quantity needed
House codeSCL-EAE-11285
ManufacturerLab Exports, Delhi

Selecting cells and resistances with the four way key

  • Comparing the emf of cells. On a potentiometer apparatus driven by a steady supply, join a Leclanche cell and a Daniel cell to separate paths of the key. A galvanometer and jockey complete the test circuit. Bring in one cell, find its balancing length l1, then move the plug and find l2 for the other. Then E1/E2 = l1/l2, where E1 and E2 are the two emfs.
  • Known against unknown resistance. Connect a resistance coil and a resistance box to two paths of the key, in series with a cell and an ammeter. Note the current with the coil selected. Then select the box and adjust it until the current is the same. The box setting then equals the coil resistance.

Setting up the four way key

  1. Place the key on a stable, dry, non-conductive bench with the supply switched off.
  2. Identify the terminals and contact paths before connecting any lead.
  3. Connect each cell, resistance or branch to its own terminal.
  4. Insert the plug for the path required, take the reading, then move the plug to the next path.

Frequently Asked Questions

How do I connect a four way key in a potentiometer?

First identify the terminals and contact paths. Join each cell to its own path so that one plug position brings only that cell into the galvanometer and jockey circuit. Join like terminals of all the cells towards the same end of the wire.

What is the purpose of a plug key in an electrical circuit?

A plug key makes and breaks a circuit by hand. On a multi-way key like this one it also chooses which path is live. Current flows only through the path whose gap is bridged by the plug.

Why must the positive terminals of all cells be connected to the same end of the potentiometer wire?

The test cell must oppose the fall of potential along the wire for a null point to exist. If the positive terminals of the driver cell and each test cell meet at the same end, balance can be found. If one cell is reversed, the galvanometer deflects the same way at every point.

Other apparatus for cell and resistance comparison

More apparatus is in the Electrical and Electronics section of the Physics Lab range.

To enquire, email [email protected] with the house code SCL-EAE-11285 and the quantity, or use the Add To Cart button on this page.

Last updated: 23 November 2026

   

Office Address

Works:11/315, Lalita Park, Laxmi Nagar, Delhi, 110092

[email protected]

Follow Us