Electrical Transformer
Product Code : SCL-EAE-11122
The Electrical Transformer is a single demonstration unit for teaching mutual induction. A 600-turn primary and a 300-turn secondary sit on a laminated U-core with a closing yoke. An isolated 6 V, 50 Hz AC supply in the primary sets up a changing flux, which induces an EMF in the secondary. Students relate the input and output voltages to the turns ratio.
Specifications of the electrical transformer
| Component | Specification |
|---|---|
| Format | Single educational demonstration unit |
| Principle | Electromagnetic induction and mutual induction |
| Core | Laminated U-core with a closing yoke |
| Primary coil | 600 turns |
| Secondary coil | 300 turns |
| Supply | Isolated 6 V, 50 Hz AC; low-voltage demonstration coils |
| Output | 3 V AC at no load for an ideal transformer; lower on load, because of winding resistance and magnetic losses |
| Concepts covered | AC voltage transformation, induced EMF, turns ratio |
| House code | SCL-EAE-11122 |
| Manufacturer | Lab Exports, Delhi |
Transformer experiments for the class
In a transformer, the two coils are linked by a magnetic core. For an ideal transformer, Vs/Vp = Ns/Np. Here V is the voltage and N the number of turns, with p for primary and s for secondary. A secondary with more turns steps the voltage up, and one with fewer turns steps it down.
- Voltage ratio and turns ratio. Place the unit on a clean, dry bench and find the primary and secondary terminals. With the supply off, join the primary to an isolated 6 V, 50 Hz AC supply, for example the AC output of a Battery Eliminator AC/DC. Set a digital multimeter to AC volts across the secondary, then switch on. Compare Vs/Vp with the turns ratio of 300 to 600. With no load, the secondary should read close to 3 V.
- Power in and out. With ideal behaviour, Vp × Ip = Vs × Is, where I is the current. Stepping the voltage up therefore steps the current down. On load, Vs falls below the ideal value, because the windings have resistance and the core has magnetic losses.
Frequently Asked Questions
Why does a transformer not work on DC?
A steady direct current sets up a constant magnetic flux, and only a changing flux induces an EMF in the secondary coil. So once the current is steady, the secondary gives no output. A DC supply can also overheat the primary, because only the resistance of the coil limits the current.
Why is the core of a transformer laminated?
Lamination reduces eddy currents. The changing flux induces small circulating currents in the core itself, and these waste energy as heat. Thin sheets, insulated from each other, break up the current paths and so cut this loss. This unit has a laminated U-core with a closing yoke.
Why is electricity transmitted at high voltage?
For the same power, a higher voltage means a smaller current, since power = voltage × current. The heat lost in the line wires is I2R, where I is the current and R the resistance of the wires. So a smaller current wastes far less energy. Transformers step the voltage up for transmission and down again near the users.
Other apparatus for induction and transformer lessons
More apparatus is in the Electrical and Electronics section of the Physics Lab range.
To enquire, email [email protected] with the house code SCL-EAE-11122 and the quantity, or use the Add To Cart button on this page.