Resistance Box 50 Ohms
Product Code : SCL-EAE-11174
This low-range resistance box puts a known resistance of up to 50 Ω into a circuit where the other resistances are also small. Seven labelled bypass toggles set any whole-ohm value from 0 to 50 Ω between two insulated 4 mm terminals. It serves as the known resistance in meter bridge and other bridge work, in Ohm's law practicals, and when comparing the resistance of short lengths of wire.
Specifications of the 50 ohm resistance box
| Component | Specification |
|---|---|
| Maximum resistance | 50 Ω |
| Type | Switch type, with seven labelled bypass toggles |
| Sections | 1, 2, 2, 5, 10, 10 and 20 Ω |
| Settings | Every whole-ohm value from 0 to 50 Ω |
| Terminals | Two insulated 4 mm terminals |
| Function | Introducing known resistance into electrical circuits |
| Suited to | Low-resistance work: Ohm's law circuits, meter bridge and other bridge measurements |
| House code | SCL-EAE-11174 |
| Manufacturer | Lab Exports, Delhi |
Low-resistance tasks for the 50 ohm box
The values on a resistance box are known, so they go straight into the calculation. A low range like this one is chosen when the resistance under test is itself small. The zero setting is not quite zero ohms. The residual resistance left with every section bypassed limits accuracy at the lowest settings.
- Known arm for a small unknown. Put the box in the left gap of a Meter Bridge or Wheatstone Bridge With Pencil Jockey as R, and the low resistance X in the right gap, with a galvanometer between the centre terminal and the jockey. Choose R close to X so that the null point lies near the centre of the wire. There a small error in reading the balancing length gives the smallest percentage error in X.
- Resistance and length of a wire. Measure the resistance of two short pieces of Constantan Wire (100gm) cut to different lengths from the same coil. The longer piece shows the larger resistance, in proportion to its length.
- Ohm's law with small resistances. Connect the box in series with an ammeter and a one way plug key, with a voltmeter across the box. Keep the current small. The lowest-rated section in circuit sets the safe limit, and the coils must not heat.
Frequently Asked Questions
What is a low-value resistance box used for?
It supplies small, known resistances for circuit work and testing. This 50 Ω box is the known resistance in bridge work on low resistances. It also serves in Ohm's law practicals and for comparing short lengths of wire.
Can a resistance box be used to check a multimeter?
Yes, for a quick check. Set a known value on the box, connect it across the multimeter leads on a resistance range, and compare the reading with the value set. With this box the check covers the low end of the range, in 1 Ω steps up to 50 Ω.
How does a resistance box work?
It holds a set of resistors of known value that can be brought into the circuit singly or in combination. On this box, each of the sections of 1, 2, 2, 5, 10, 10 and 20 Ω has its own bypass toggle. The value in circuit is the total of the sections not bypassed.
How should a resistance box be set before the circuit is switched on?
Set it to its highest value, 50 Ω with no section bypassed, so that the first current is as small as possible. Check that all contacts and terminals are clean and tight, then reduce the resistance to the value needed. Switch off between changes.
Does resistance depend on the dimensions of the conductor?
Yes. For a wire of one material at a fixed temperature, resistance is directly proportional to its length and inversely proportional to its area of cross-section. Doubling the length doubles the resistance, while a thicker wire of the same length has less resistance.
More apparatus for bridge work
More apparatus is in the Electrical and Electronics section of the Physics Lab range.
To enquire, email [email protected] with the house code SCL-EAE-11174 and the quantity, or use the Add To Cart button on this page. Tender buyers can also see the Tenders and OEM page.
Last updated: 23 November 2026