Portable Wheatstone Bridge

Portable Wheatstone Bridge

Product Code : SCL-EAE-11297

In this portable Wheatstone bridge the unknown resistor forms one arm of a four-arm network. A ratio selector sets two arms and decade controls set the third, until the built-in centre-zero galvanometer reads zero. Because the reading is taken at zero deflection, the DC resistance found rests on the manganin arms, not on the galvanometer scale.

Specifications of the portable Wheatstone bridge

ComponentSpecification
Measurement principleFour-arm Wheatstone bridge, null-balance method
MeasuresDC resistance
Resistance coilsManganin wire windings
Balance indicatorBuilt-in centre-zero moving-coil galvanometer, showing the direction of imbalance
Arm settingsDecade controls and a ratio selection arrangement
Operating keysSeparate battery and galvanometer keys
HousingPortable protective enclosure
Measuring range, ratio steps and accuracyConfirmed with the quotation
House codeSCL-EAE-11297
ManufacturerLab Exports, Delhi

Bench exercises with the ratio-arm bridge

Call the two ratio arms P and Q, the decade arm R and the unknown S. A cell drives one diagonal of the loop and the galvanometer sits across the other. With no galvanometer current, P/Q = R/S, so S = R × Q/P.

  • Series and parallel checks. Measure two resistance coil units one at a time, then joined in series and in parallel. Compare the results with S1 + S2 and S1S2/(S1 + S2). The ready-wired resistors of the Resistance in Series and Parallel Apparatus can be checked the same way.
  • Copper against manganin. Wind a coil of DCC copper wire and one of manganin wire. Put each coil in a dry test tube and measure it at room temperature, then again with the tube standing in warm water. The copper value rises clearly, while the manganin value hardly moves, which is why the bridge arms are manganin.

Finding the null point

  1. Set the bridge on a stable, dry bench and connect the unknown resistor to its terminals.
  2. Pick a ratio and a starting value on the decade controls.
  3. Hold the battery key down, tap the galvanometer key, and see which way the pointer swings.
  4. Change the decades until the pointer stays on zero. If balance cannot be reached, change the ratio and try again.
  5. Work out the unknown resistance from the ratio and decade settings.

Documentation and supply

Most Lab Exports products carry a one-year manufacturer warranty.

Lab Exports manufactures the portable Wheatstone bridge at its works in Laxmi Nagar, Delhi, and supplies it to schools, colleges and universities in India and 60+ countries, handling the export documents for each shipment. More about the company is on the About Lab Exports page.

Frequently Asked Questions

What is the main purpose of a Wheatstone bridge?

It measures an unknown resistance by comparing it with known resistances. The same balanced-bridge idea is also used in sensor circuits, such as strain gauges, where a small change in one arm upsets the balance.

What should be checked on a portable Wheatstone bridge before use?

Check that the galvanometer pointer rests on centre zero, that the keys and decade controls make clean contact, and that the terminals are tight. Keep the leads to the unknown short, because their resistance adds to the reading.

What precautions should be taken when using the Wheatstone bridge?

Press the battery key before the galvanometer key, so the currents settle before the galvanometer is connected. Tap the galvanometer key briefly, and release both keys between readings so the coils do not warm up.

Why is a Wheatstone bridge more accurate than a meter reading?

It is a null method. At balance no current flows in the galvanometer, so its calibration does not enter the result. The answer depends only on the known arms, and here those are stable manganin coils.

What is null deflection in a Wheatstone bridge?

It is the state in which the galvanometer shows no deflection. The two ends of the galvanometer are then at the same potential, so P/Q = R/S and the unknown can be worked out.

Apparatus for these bridge exercises

More apparatus is in the Electrical and Electronics section of the Physics Lab range.

To enquire, email [email protected] with the house code SCL-EAE-11297 and the quantity, or use the Add To Cart button on this page.

Last updated: 23 November 2026

   

Office Address

Works:11/315, Lalita Park, Laxmi Nagar, Delhi, 110092

[email protected]

Follow Us