Loading Inductor 1.2KVAR Bank
Product Code : SCL-EAE-11308
This loading inductor bank is an inductive AC reactive load rated at 1.2 kVAR. On a compatible AC source its current lags the voltage. Students use it to study inductive reactance and reactive power, and to watch inductive and capacitive reactive power cancel when a matching capacitive load is added.
Specifications of the 1.2 kVAR inductor bank
| Component | Specification |
|---|---|
| Load type | Inductive AC reactive load |
| Rated reactive capacity | 1.2 kVAR |
| Load characteristic | Lagging current |
| Can load | Alternators, generators, transformers and AC trainers, after rating checks |
| Operating voltage, frequency, phase, load steps and terminal arrangement | Confirmed in the quotation; check them before connection |
| House code | SCL-EAE-11308 |
| Manufacturer | Lab Exports, Delhi |
AC circuit experiments with the inductor bank
The opposition an inductor offers to AC is its inductive reactance, XL = 2πfL, where f is the supply frequency and L the inductance. At a voltage V across it, the reactive power taken is Q = V2/XL.
- Reactance from meter readings. With the supply off, measure the resistance of the winding on a digital multimeter. Then energise the bank, read V and I, and take V/I as its impedance. As the winding resistance is small, this is close to XL.
- Inductance of the bank. Note the supply frequency f and work out L = XL/(2πf) from the reactance just found.
- Reactive power balance. Connect the Loading Capacitor 1.2KVAR Bank alongside it. When both are rated for the same voltage and frequency, their reactive powers nearly cancel and the source supplies mainly active power.
Documentation and supply
Most Lab Exports products carry a one-year manufacturer warranty.
Lab Exports manufactures the 1.2 kVAR loading inductor bank at its works in Laxmi Nagar, Delhi, and supplies it to engineering colleges, polytechnics and technical institutes in India and 60+ countries, handling the export documents for each shipment. More about the company is on the About Lab Exports page.
Frequently Asked Questions
How do you convert kVAR to kVA?
Combine it with the active power: kVA = √(kW2 + kVAR2). On a nearly pure inductive load such as this 1.2 kVAR bank, the active power is small, so the kVA drawn is only a little more than the kVAR.
Should an inductor bank have an air core or an iron core?
Both are used. An iron core gives more inductance in a small enclosure. An air core stays linear without saturation but is larger and spreads a stray magnetic field. Ask which core this bank has when you enquire.
What is the inductive reactance for pure DC?
Zero. Reactance equals 2πfL and the frequency of DC is zero, so only the small winding resistance would limit the current. Never connect this AC bank to a DC supply.
What is the formula for inductive reactance?
XL = 2πfL, in ohms, where f is the frequency in hertz and L the inductance in henries. Reactance rises in step with frequency, so the same coil passes less current on a higher-frequency supply.
Loads for comparison in AC circuit work
More apparatus is in the Electrical and Electronics section of the Physics Lab range.
To enquire, email [email protected] with the house code SCL-EAE-11308 and the quantity, or use the Add To Cart button on this page.
Last updated: 23 November 2026