Callendar and Barne's Apparatus (Continuous Flow)
Product Code : EL-H-10402
The Callendar and Barnes apparatus finds the specific heat capacity of a liquid by the continuous-flow method. Liquid flows steadily through a borosilicate glass tube past a spirally wound nichrome coil about 40 cm long. A brass level tank on stand keeps the flow steady, and the tube lies in a felt-lined wooden case.
Specifications of the continuous-flow apparatus
| Component | Specification |
|---|---|
| Flow tube | Borosilicate glass, open at both ends |
| Heating coil | Nichrome wire, about 40 cm (400 mm) long, wound spirally along the tube axis; detachable |
| Case | Wooden, lined with felt, with a hinged cover |
| Level tank | Brass, on stand, included |
| Assembly | Leak-proof when fully assembled |
| Supplied without | Thermometers and meters |
| House code | EL-H-10402 |
| Manufacturer | Lab Exports, Delhi |
Specific heat of a liquid by continuous flow
Liquid enters the tube at temperature T1, is heated by the coil and leaves at a steady T2. At steady state VI = mc(T2 - T1) + h. Here V and I are the coil voltage and current, and m is the mass of liquid flowing per second. The specific heat of the liquid is c, and h is the steady heat loss per second.
- Fill the brass level tank and join it to the inlet of the glass tube with Rubber Tubing, so that liquid flows through at a steady rate.
- Place thermometers at the inlet and outlet ends. Connect the coil to an IC Regulated Power Supply through an Ammeter and a Rheostat Nichrome Wire Groove Type, with a Voltmeter across the coil.
- Switch on and wait until the outlet temperature is steady. Record V, I, T1 and T2.
- Run the outflow into a beaker for a time read on an Analog Stop Clock. Weigh the liquid on a Physical Balance; its mass divided by the time gives m.
- Change the flow rate and the current together so that T2 - T1 stays the same, and take a second set of readings.
With the same temperature rise in both runs, h cancels. Call the readings of the two runs V1, I1, m1 and V2, I2, m2. Then c = (V1I1 - V2I2) / ((m1 - m2)(T2 - T1)).
Assembly and care
The apparatus is leak-proof once fully assembled, so check every joint before the first run. Let liquid flow through the tube before switching on the current, so that the coil is never heated dry. The nichrome coil is detachable for maintenance or replacement.
Documentation and supply
Installation instructions and a manual are supplied with the apparatus. Most Lab Exports products carry a one-year manufacturer warranty.
Lab Exports manufactures the Callendar and Barnes apparatus at its works in Laxmi Nagar, Delhi, and supplies it to colleges and universities in India and 60+ countries, handling the export documents for each shipment. More about the company is on the About Lab Exports page.
Frequently Asked Questions
What are the components of a Callendar and Barnes apparatus?
The core parts are a glass flow tube, a spiral heating coil along its axis, inlet and outlet points for thermometers, an insulated case and a constant-level tank. Here the tube is borosilicate glass, the nichrome coil is about 40 cm long and the brass level tank on stand is included.
What has to be added before the apparatus can be used?
It is supplied without thermometers or meters. Add two sensitive thermometers for the inlet and outlet, a DC supply with an ammeter and a voltmeter, and a stop clock, beaker and balance to find the flow rate.
Why is the water equivalent of the calorimeter not needed?
At steady state every part of the tube and coil stays at a constant temperature, so they take in no further heat. The electrical energy goes only into the flowing liquid and the steady loss h.
Why are two sets of readings taken with the same inlet and outlet temperatures?
With the same temperatures, the heat lost to the surroundings, h, is the same in both runs. Subtracting one energy equation from the other removes h and leaves only the specific heat c to find.
Why is the heating coil wound as a spiral?
A spiral fits a long wire into the tube and gives a large surface in contact with the liquid. It also mixes the flow, so the liquid reaching the outlet thermometer is at one even temperature.
Other apparatus for calorimetry practicals
More apparatus is in the Heat section of the Physics Lab range.
To enquire, email [email protected] with the house code EL-H-10402 and the quantity, or use the Add To Cart button on this page.