Ohms Law Apparatus
Product Code : EL-LM-10394
This Ohm's law apparatus verifies V = IR with a wire-wound potentiometer that sets the voltage across the resistance under test. The readings come from two moving-coil meters, a sensitive 5 V voltmeter and a 500 mA milliammeter. The supply gives 1.5, 3 or 4.5 V through a step-down transformer, and the circuit diagram is printed on the metal case.
Specifications of the Ohm's law apparatus
| Component | Specification |
|---|---|
| Meters | Two moving-coil meters: voltmeter and milliammeter |
| Voltmeter | 5 V, sensitive |
| Milliammeter | 500 mA |
| Voltage control | Wire-wound potentiometer |
| Supply | 1.5 V, 3 V or 4.5 V, with step-down transformer and lead wire |
| Terminals | 4 mm sockets for the DC supply and for the unknown resistance |
| Case | Spray-painted metal box with ON/OFF switch and printed circuit diagram |
| House code | EL-LM-10394 |
| Manufacturer | Lab Exports, Delhi |
Practicals on the potentiometer-controlled set
- Setting the voltage with the potentiometer. Connect a Resistance Box Plug Type to the 4 mm sockets, set to a suitable value. Turn the potentiometer slowly from one end of its track to the other. The voltmeter reading rises smoothly, and the milliammeter follows it step by step.
- Why the temperature must stay steady. Connect a length of nichrome wire and leave the current on for a while at a higher setting. As the wire warms, its resistance rises a little, so V/I creeps upward. That is the reason Ohm's law needs a steady temperature, and why the switch is turned off between readings.
Frequently Asked Questions
Why does an Ohm's law apparatus have a circuit diagram printed on the panel?
The diagram cuts wiring mistakes in class. Students can see where the supply, the potentiometer and the two meters sit before they connect anything. On this apparatus it is printed on the spray-painted metal case, beside the ON/OFF switch and the sockets.
What can be connected to the 4 mm sockets of an Ohm's law apparatus?
Test resistors, resistance coils and lengths of resistance wire fitted with 4 mm plugs. This apparatus has separate 4 mm sockets for the DC supply and for the unknown resistance. Do not let the current go past 500 mA, the full range of the milliammeter.
Why is a milliammeter used instead of an ammeter?
Because the currents in this experiment are small. A low supply voltage across a test resistance gives only milliamperes, and a milliammeter scale shows them clearly. This apparatus uses a 500 mA moving-coil milliammeter.
How is a potentiometer different from a rheostat?
A rheostat works as a variable resistance in series and controls the current. A potentiometer uses all three terminals as a voltage divider, so the output can be set smoothly from zero upward. This apparatus uses a wire-wound potentiometer to set the applied voltage.
What happens if the needle deflects in the opposite direction?
The meter is connected the wrong way round. Switch off at once and swap the leads, so that positive goes to positive. A reversed moving-coil meter pushes its pointer against the stop, which can bend the pointer.
More wire samples for this apparatus
More apparatus is in the Lab Meters section of the Physics Lab range.
To enquire, email [email protected] with the house code EL-LM-10394 and the quantity, or use the Add To Cart button on this page.