MR100 Desk Stand Meter
Product Code : SCL-EAE-11354
The MR100 desk stand meter is an analog moving-coil instrument built for careful scale reading. Its knife-edge pointer and inclined dial let students line the pointer up with a graduation, square-on, from the bench. The ABS plastic stand carries front brass terminals, and the measuring function and range are chosen when ordering.
Specifications of the MR100 desk stand meter
| Component | Specification |
|---|---|
| Meter type | Analog moving-coil desk stand meter |
| Dial | Inclined analog dial |
| Pointer | Knife-edge pointer |
| Stand | ABS plastic |
| Terminals | Front-mounted brass terminals |
| Function and range | Chosen when ordering |
| House code | SCL-EAE-11354 |
| Manufacturer | Lab Exports, Delhi |
Scale-reading practice with the MR100
Stand the meter on a firm bench and confirm that it reads zero. Switch off the circuit before joining leads to the brass terminals, and observe polarity.
- Seeing parallax. Set a steady reading. Let one student read it from straight in front and another from well to one side, then compare. The knife edge looks thinnest, and the reading is right, only when viewed square-on.
- Value of a division. Before each set of readings, work out what one small division is worth on the range in use. Then read to the nearest division, or to a half division where the marks are wide enough.
- Readings in a resistance circuit. Ordered as an ammeter, the meter goes in series with a resistance coil, a rheostat and a battery eliminator. Ordered as a voltmeter, it goes across the coil. Step the rheostat and record each reading.
Frequently Asked Questions
Why do analogue meters have a knife-edge pointer?
A knife-edge pointer is very thin when seen square-on, so it can be lined up exactly with one scale mark. Seen from the side it looks wider and seems to sit against another mark. It is there to reduce parallax and reading errors.
Which functions can a desk stand meter be ordered for?
Moving-coil desk stand meters are commonly made as ammeters, voltmeters or galvanometers. The function and range of the MR100 are chosen when ordering, so state the quantity and the range your practical needs when you enquire.
What is parallax error on a meter?
It is a reading error caused by looking at the pointer from an angle. The pointer sits a little above the scale, so from the side it appears against the wrong mark. Look straight at the dial; the inclined dial of the MR100 makes this easy from the bench.
How do you work out what each division is worth?
Pick two numbered marks and subtract their values. Then count the small spaces between those marks and divide the difference by that number. Work this out for the range in use before reading, and count divisions from the last numbered mark.
Other lab meters for physics practicals
More apparatus is in the Electrical and Electronics section of the Physics Lab range.
To enquire, email [email protected] with the house code SCL-EAE-11354 and the quantity, or use the Add To Cart button on this page.
Last updated: 23 November 2026
