Loading Rheostat 6.5KW Bank
Product Code : SCL-EAE-11310
This loading rheostat bank is a resistive load bank with a power capacity of 6.5 kW. It applies a real-power load to a generator or alternator, and all the energy it absorbs ends up as heat. Students compare no-load and loaded running and measure terminal voltage, output power and efficiency.
Specifications of the 6.5 kW loading rheostat bank
| Component | Specification |
|---|---|
| Load type | Resistive electrical load |
| Power capacity | 6.5 kW |
| Absorbed energy | Turned into heat |
| Use | Loading generators, alternators and training systems after rating checks |
| Voltage, current, phase, resistance range, load-control method, cooling and duty cycle | Confirmed in the quotation |
| House code | SCL-EAE-11310 |
| Manufacturer | Lab Exports, Delhi |
Efficiency and load tests on machines
A resistive load takes only real power, P = VI, where V and I are the voltage and current of the bank. The electrical output of a generator is then simply the product of the load voltmeter and ammeter readings, with no power factor to allow for.
- Efficiency of a motor-generator set. Measure the input to the drive motor while the bank is loaded step by step. Read the generator output on a digital LED ammeter and a digital LED voltmeter. Overall efficiency at each step is the electrical output divided by the motor input.
- Internal characteristic. With the machine stopped, measure the armature resistance on a digital multimeter. At each load step, add the armature resistance drop to the terminal voltage. Plot this generated emf against armature current.
- No load against full load. Compare the readings at no load with those at each load step. They show how voltage, current and output change as the bank takes more power.
Setting up the bank for a machine test
- Check the voltage, current, phase and power ratings of the bank against the machine.
- Place the bank where air can circulate freely, away from anything that its heat could damage.
- With the machine stopped, connect the bank through an ammeter and voltmeter.
- Bring the machine to rated speed and voltage, then add load in steps and record input and output readings at each one.
Frequently Asked Questions
How do you choose the kW rating of a resistive load bank?
Match it to the real power, in kW, that the machine under test gives at full load, not to its kVA. A resistive load works at unity power factor. This bank has a power capacity of 6.5 kW; its voltage, current and phase are confirmed in the quotation.
Resistive or reactive load bank: which one is needed?
A resistive bank such as this one tests real power output, efficiency and regulation at unity power factor. A reactive bank adds lagging or capacitive current. Many machine labs keep both, so that alternators can also be tested below unity power factor.
How is the heat from a loading rheostat bank removed?
By air flowing over the resistance elements, either naturally or with a fan, and some large units are liquid cooled. Everything the bank absorbs becomes heat. The cooling method and duty cycle of this bank are confirmed in the quotation.
What is the difference between external and internal characteristics?
The external characteristic is terminal voltage plotted against load current. The internal characteristic is the emf actually generated plotted against armature current. It lies above the external curve by the voltage drop in the armature resistance.
What is the loading arrangement used in a DC motor test?
Two are common. A brake test uses a belt and spring balances on a brake drum fitted to the motor shaft. Otherwise the motor drives a generator whose output feeds a resistive bank such as this one. Each load step then raises the torque the motor must supply.
Other resistive loads for machine tests
More apparatus is in the Electrical and Electronics section of the Physics Lab range.
To enquire, email [email protected] with the house code SCL-EAE-11310 and the quantity, or use the Add To Cart button on this page.