MR80 Desk Stand Meter
Product Code : SCL-EAE-11356
The MR80 desk stand meter is a compact moving-coil meter with an inclined dial and pointer. A transparent cover protects the pointer and scale, and front red and black terminals make the polarity plain. Its small body takes little bench space. The measuring function and calibrated range are specified when ordering.
Specifications of the MR80 desk stand meter
| Component | Specification |
|---|---|
| Principle | Moving-coil indication |
| Display | Inclined analog dial with pointer |
| Cover | Transparent protective meter cover |
| Terminals | Front-mounted red and black terminals |
| Format | Compact desk stand |
| Function and calibrated range | Specified when ordering |
| House code | SCL-EAE-11356 |
| Manufacturer | Lab Exports, Delhi |
Circuit practicals with MR80 meters
- The zero check. Before any reading, see that the pointer rests exactly on zero. Make this the first habit of every practical, then join the meter with the circuit switched off.
- Several meters at once. Because the stands are compact, a few MR80 meters can sit side by side. Build a series and parallel circuit from a battery eliminator and two resistance boxes, with meters in the main lead and in each branch, and read them together.
- Analog beside digital. Take the same reading on the MR80 and on a digital multimeter. Compare how finely each can be read, and discuss resolution and reading error.
Join the meter in series with the load when it is set up for current, or across the component when it is set up for voltage. Switch on gradually while watching the pointer, and switch off before disconnecting.
Documentation and supply
Most Lab Exports products carry a one-year manufacturer warranty.
Lab Exports manufactures the MR80 Desk Stand Meter at its works in Laxmi Nagar, Delhi, and supplies it to schools, colleges and universities in India and 60+ countries, handling the export documents for each shipment. More about the company is on the About Lab Exports page.
Frequently Asked Questions
How do you protect an analogue meter?
Treat it as a delicate instrument. Do not drop or knock it, check polarity and range so the pointer never strikes its stops, and switch off before changing connections. On the MR80 the transparent cover also shields the pointer and scale during handling.
Why should an analogue meter be kept away from magnets?
A moving-coil meter works with a permanent magnet inside. Strong outside fields from magnets, transformers or leads carrying heavy current can disturb the pointer and give false readings. Keep such items clear of the meter on the bench and in storage.
What is zero error in a voltmeter or ammeter?
It is a reading shown when nothing is connected, because the pointer does not rest exactly on zero. Check the pointer before each practical. If it is off zero, correct it where the meter allows, or subtract the error from every reading.
What are common mistakes when using an analogue meter?
The usual ones are joining an ammeter in parallel or a voltmeter in series, reversing the polarity, choosing too small a range and skipping the zero check. Switching on gradually while watching the pointer catches most of them before any harm is done.