Brass Wire (100 gm)
Product Code : SCL-EAE-11209
This brass wire is a 100 g net spool of copper-zinc alloy wire, cut to length for physics practicals. It comes in 24 or 26 SWG, hard-drawn or annealed. It serves as a sonometer wire, as a test wire in elasticity and expansion work, and as a comparison sample in resistance practicals. Brass resists atmospheric corrosion better than iron or steel wire.
Specifications of the brass wire
| Component | Specification |
|---|---|
| Material | Brass (copper-zinc alloy) |
| Net weight | 100 g per spool, one gauge per spool |
| Form | Wound on a centre-hub spool |
| Packing | Clear protective film wrap |
| Wire gauge | 24 SWG (0.559 mm bare diameter), or 26 SWG (0.457 mm) as the finer option |
| Temper | Hard-drawn (hard temper), for a tensioned sonometer wire, or annealed (soft), for winding and forming |
| House code | SCL-EAE-11209 |
| Manufacturer | Lab Exports, Delhi |
Practicals that use the brass wire
Draw off only the length each set-up needs and keep the rest on the spool, where it stays clean and straight.
- Sonometer wire. Use the hard-drawn wire here, as it takes less permanent set under the load. Stretch a length over the bridges of a sonometer apparatus and hang a load from its free end. Sound a fork from a tuning fork set and press its stem on the sounding board. Move a bridge until a paper rider on the wire jumps off. Repeat at several loads. For one fork, the resonating length rises as the square root of the tension. Find the mass per unit length by weighing a measured piece, as this allows for the actual alloy and diameter.
- Resistance of brass against nichrome. Cut equal lengths of brass and nichrome wire. Find the resistance of each on a meter bridge, and read each diameter at several points with a screw gauge. Then the resistivity ρ = Rπr2/L, where R is the resistance, r is half the mean diameter and L is the length. Brass gives a far lower value, because it conducts far better than nichrome.
- Elasticity and expansion. A clamped length can also be the test wire in Young's modulus work, for example on a Young's modulus apparatus (vernier type). It is also used in linear expansion set-ups heated by a steam jacket. Temper changes the yield strength and the permanent set, so record whether the wire is hard-drawn or annealed.
Cutting a length from the spool
- Fit the spool on a rod or stand so that it turns freely.
- Pull out the length needed, keeping the wire straight as it comes off.
- Cut it cleanly with wire cutters and straighten any kinks.
- If the experiment needs the cross-section, take screw gauge readings of the diameter at several points and use their mean.
Documentation and supply
Most Lab Exports products carry a one-year manufacturer warranty.
Lab Exports manufactures the brass wire (100 g) at its works in Laxmi Nagar, Delhi, and supplies it to schools, colleges and universities in India and 60+ countries, handling the export documents for each shipment. More about the company is on the About Lab Exports page.
Frequently Asked Questions
What gauge of brass wire should be ordered for a sonometer?
Order 24 SWG (0.559 mm) or the finer 26 SWG (0.457 mm) in the hard-drawn temper, which suits a tensioned sonometer wire. A thinner wire has less mass per unit length. At the same length and tension it therefore vibrates at a higher frequency.
What are the main properties of brass?
Brass is an alloy of copper and zinc. It conducts electricity less well than pure copper but far better than resistance alloys such as nichrome. It does not rust, it resists atmospheric corrosion better than iron or steel, and it is practically non-magnetic.
What are the disadvantages of brass wire?
For electrical work, its resistance is higher than that of copper, so it is a poor choice for leads and coil windings. Its resistance also changes with temperature far more than that of constantan or manganin. So it is not used for bridge wires or standard resistances.
Which wire is used in a sonometer?
A stretched steel or brass wire is the usual choice. Both have a uniform mass per unit length and stay elastic under the hanging load, so the frequency follows the laws of vibrating strings. Either can be used with tuning forks.
Why is a non-magnetic wire used in the AC sonometer experiment?
So that only the current in the wire makes it vibrate. The wire carries alternating current between the poles of a magnet, and the force on it reverses every half cycle. A magnetic wire would also be pulled by the magnet itself, which upsets the vibration.
Other wire packs for the physics lab
More apparatus is in the Electrical and Electronics section of the Physics Lab range.
To enquire, email [email protected] with the house code SCL-EAE-11209 and the quantity, or use the Add To Cart button on this page.
Last updated: 23 November 2026