Loading Inductor 2.5KVAR Bank

Loading Inductor 2.5KVAR Bank

Product Code : SCL-EAE-11309

Rated at 2.5 kVAR, this loading inductor bank makes the current lag the voltage in a compatible AC circuit. Students use it to tell watts, volt-amperes and VAR apart, to measure a lagging power factor and then to correct it with a capacitor bank.

Specifications of the 2.5 kVAR inductor bank

ComponentSpecification
Equipment categoryInductive reactive-load bank
Rated reactive capacity2.5 kVAR
Load characteristicInductive, lagging
PartsIntegrated inductive loading assembly, connection terminals, load-selection switches or controls where included
Rated voltage, current, frequency, phase arrangement, load increments and coolingConfirmed against the final technical quotation
House codeSCL-EAE-11309
ManufacturerLab Exports, Delhi

Measuring and correcting a lagging power factor

Three meter readings give three powers. The wattmeter shows active power P in watts. The voltmeter and ammeter readings multiplied give apparent power S in volt-amperes. Reactive power Q in VAR is then √(S2 - P2), and the power factor is P/S.

  • Correction in steps. Wire an analog ammeter panel, an analog voltmeter panel and a portable analog wattmeter into the supply circuit. Take a first set of readings with the inductor bank alone. Then add a capacitor bank such as the Loading Capacitor 3KVAR Bank in parallel, one step at a time. The ammeter reading falls while the wattmeter reading stays almost the same, and the power factor rises.
  • Going too far. Keep adding capacitance past unity power factor. The line current rises again and now runs ahead of the voltage, which shows why correction has to be sized with care.

Documentation and supply

Most Lab Exports products carry a one-year manufacturer warranty.

Lab Exports manufactures the 2.5 kVAR loading inductor bank at its works in Laxmi Nagar, Delhi, and supplies it to engineering colleges, polytechnics and technical institutes in India and 60+ countries, handling the export documents for each shipment. More about the company is on the About Lab Exports page.

Frequently Asked Questions

What is the difference between kVA, kVAR and kW?

kW is active power, the part turned into heat, light or work. kVAR is reactive power, exchanged with magnetic or electric fields every cycle. kVA is apparent power, voltage times current.

What is needed for a power factor correction experiment with an inductor bank?

The inductor bank as the lagging load, a capacitor bank to connect in parallel, and a voltmeter, ammeter and wattmeter in the supply line. A resistive load is often added so that the uncorrected power factor is not close to zero.

What happens to supply current and active power after switching in the capacitor?

The supply current falls, because the capacitor provides part of the reactive current the inductor bank needs. The active power stays almost the same, since an ideal capacitor takes no real power. The power factor therefore rises.

How do you find the practical power factor during the experiment?

Divide the wattmeter reading by the product of the voltmeter and ammeter readings: power factor = P/(VI). With the inductor bank alone the result is lagging. Record it again after each capacitor step.

Why should over-compensation be avoided?

Too much capacitance turns a lagging power factor into a capacitive one. The line current rises again, and on a supply network the voltage can rise too. Correction is sized to bring the power factor close to unity, not past it.

Other units for power factor practicals

More apparatus is in the Electrical and Electronics section of the Physics Lab range.