Potentiometer Apparatus
Product Code : SCL-EAE-11258
This potentiometer apparatus finds potential differences from balance lengths along a uniform resistance wire that carries a steady current. At balance the galvanometer shows no deflection. Its two main practicals are the ratio of the EMFs of two cells and the internal resistance of a primary cell.
Specifications of the potentiometer apparatus
| Component | Specification |
|---|---|
| Primary function | EMF comparison and null-deflection experiments |
| Principle | Potential gradient and balance-length method |
| Measuring element | Uniform resistance wire |
| Experiments | Ratio of the EMFs of two cells; internal resistance of a primary cell |
| Wire length, scale range and accessories | Confirmed by email for the current configuration |
| House code | SCL-EAE-11258 |
| Manufacturer | Lab Exports, Delhi |
Balance-length experiments on this apparatus
A steady driver current makes the potential fall evenly along the wire. The fall per unit length is the potential gradient k. A cell joined against the wire through a galvanometer balances at the length l where its EMF E = kl, and at that point it gives no current.
- Setting up the driver circuit. Connect a Battery Eliminator, or another low-voltage source, across the ends of the wire, with a One Way Plug Key and a rheostat in series. The rheostat sets the current, and so the potential gradient, for the whole set of readings.
- Ratio of two EMFs. Take a Leclanche Cell 1.5V and a Daniel Cell, with like poles joined to the same end of the wire. Switch them in turn through a Two Way Plug Key to the galvanometer and jockey. With balance lengths l1 and l2, E1/E2 = l1/l2.
- Internal resistance of a cell. Note the balance length l1 with the terminals of the cell left open. Then place a known resistance R from a Resistance Box Plug Type across those terminals. The cell now drives a current through R, its terminal voltage drops, and the balance moves to a shorter length l2.
To find each balance length, bring the jockey down briefly on one spot of the wire and read the galvanometer. Lift it before trying the next spot, never rub it along the wire, and open the main key between readings.
Frequently Asked Questions
What is supplied with the potentiometer apparatus?
The wire length, scale range and supplied accessories depend on the current configuration, so they are confirmed by email with the house code. For the experiments you will also need a driver supply, a key, a rheostat, a galvanometer and a jockey, if one is not included.
Why must the EMF of the driver cell be greater than the EMF being measured?
Because the balance point has to lie on the wire. The total fall of potential along the wire comes from the driver supply. If that fall is smaller than the EMF under test, no length of wire can match it and no balance is found.
What is the formula for internal resistance using a potentiometer?
The internal resistance is r = R(l1 - l2)/l2. Here l1 is the balance length with the cell on open circuit, and l2 is the balance length with a known resistance R connected across the cell.
How is the sensitivity of a potentiometer affected by the length of the wire?
A longer wire makes it more sensitive. The same fall of potential is spread over more length, so the potential gradient is smaller and a small change in EMF moves the balance point further. Lowering the driver current with the rheostat has the same effect.
What will result if the cross-section of the potentiometer wire is not uniform?
The potential will not fall evenly along the wire, so the fall per centimetre changes from place to place. Balance lengths are then no longer proportional to the EMFs, and the ratio or internal resistance worked out from them is wrong.
Other items for EMF and internal resistance practicals
More apparatus is in the Electrical and Electronics section of the Physics Lab range.
To enquire, email [email protected] with the house code SCL-EAE-11258 and the quantity, or use the Add To Cart button on this page. Tender buyers can also see the Tenders and OEM page.
Last updated: 23 November 2026