Battery Eliminator 2–12V 2A

Battery Eliminator 2–12V 2A

Product Code : SCL-EAE-11333

Each lesson starts from the same voltage with this eliminator, unlike dry cells that run down. It is a low-voltage DC supply for school and college circuits. A rotary selector gives 2, 4, 6, 8, 10 or 12 V plus a 0 V position, at up to 2 A. It has marked terminals, a separate ON/OFF switch and a fuse on the front panel.

Specifications of the 2-12 V battery eliminator

ComponentSpecification
Output typeDC
Selectable output0, 2, 4, 6, 8, 10 and 12 V, in 2 V steps
Maximum output current2 A
Output connectionsPositive and negative terminals, marked for polarity
ControlsRotary voltage selector and separate ON/OFF switch
ProtectionFront-panel fuse
House codeSCL-EAE-11333
ManufacturerLab Exports, Delhi

Using the 2 V steps in practicals

  • Voltages between the steps. Connect the Rheostat 8 Inches across the output as a potential divider. Take the supply for the experiment from one end and the sliding contact, and set the exact voltage on a voltmeter.
  • Electrolysis of water. Fill the Hoffman Voltameter with acidified water and connect its electrodes to the terminals, positive to the anode. Start at a low step and raise it until gas collects steadily, then compare the two volumes.

Frequently Asked Questions

Why does the voltage sometimes drop when a heavy load is connected?

Every supply has some internal resistance in its own circuit and wiring. As the load draws more current, more voltage is lost inside, so less appears at the terminals. The drop grows as the current nears the 2 A limit of this unit.

Can a battery eliminator be used for potentiometer experiments?

Yes, as the driver supply that sends a steady current through the potentiometer wire. It cannot replace the cells whose emf is being measured or compared. Its output must also stay steady during a set of readings, or the balance point will drift.

Is a 2-12 V battery eliminator IC regulated or non-regulated?

Both kinds are sold. In a non-regulated unit the output falls somewhat as the load current rises, and an IC regulator corrects for that fall. This page does not state regulation for this model, so ask when you enquire if your practicals need a regulated supply.

Why does the fuse of a battery eliminator keep blowing?

Usually because the load draws more than the rated current, or because the output is shorted by a wiring fault. Check the circuit and its resistance before switching on again. Replace the fuse only with one of the same rating, never with wire.

Other supplies and meters for electricity practicals

More apparatus is in the Electrical and Electronics section of the Physics Lab range.

To enquire, email [email protected] with the house code SCL-EAE-11333 and the quantity, or use the Add To Cart button on this page.