Backhaus Towel Clamp
Product Code : EL-SI-10953
The Backhaus towel clamp, also called a towel clip or towel forceps, fixes surgical drapes and towels around the incision and to each other, with or without piercing the skin. This springy 13 cm clamp has a fine single tooth on each jaw and a lockable hard ratchet. It is made of hardened martensitic steel with 13% chromium.
Specifications of the Backhaus towel clamp
| Component | Specification |
|---|---|
| Type | Springy towel clamp, Backhaus pattern |
| Length | 13 cm |
| Jaws | Pointed, with a fine single tooth on each jaw |
| Lock | Hard ratchet, lockable |
| Material | Martensitic steel, quenched (hardened), magnetic |
| Composition | 0.20% carbon, 13% chromium |
| House code | EL-SI-10953 |
| Manufacturer | Lab Exports, Delhi |
How the towel clamp is used in theatre
Once the patient is prepared, the drapes leave only the operative area exposed. Towel clamps then hold the layers so that this sterile field does not shift while the team works.
- Fixing the drapes. Towels and a woven surgical drape are laid around the incision site, and a clamp is placed at each corner where layers overlap. The pointed jaws pass through the fabric and, where needed, take a small bite of skin to anchor the drape.
- Holding tubing and cables. Theatre staff also use the clamp as a drape clamp for suction tubing and cables, so these stay in place on the drape without being held.
- Setting out and reprocessing. Before the case the clamps are laid out with the rest of the set on an Instrument Tray Stainless Steel. After the case the ratchet is opened, the clamp is cleaned, and it is sterilised again, for example in a stainless steel autoclave.
Documentation and supply
Most Lab Exports products carry a one-year manufacturer warranty.
Lab Exports manufactures the Backhaus towel clamp at its works in Laxmi Nagar, Delhi, and supplies it to hospitals, clinics and medical colleges in India and 60+ countries, handling the export documents for each shipment. More about the company is on the About Lab Exports page.
Frequently Asked Questions
What is a towel clip used for in surgery?
It keeps towels and drapes in position around the incision, so the sterile field stays put for the whole operation. The Backhaus pattern can grip the drape alone or also take a small bite of skin. Staff also use it to hold suction tubing and cables on the drape.
What types of towel clamps are there?
The two common forms are the Backhaus pattern and cross-action clips. The Backhaus pattern has finger rings, a ratchet lock and pointed tips that pass through the drape. Cross-action clips, such as the Jones pattern, are closed by their own spring. Non-penetrating clips have blunt jaws that grip the drape without piercing it. This 13 cm clamp is a springy Backhaus pattern.
How does the ratchet lock work?
When the finger rings are pressed together, the teeth of the hard ratchet engage and hold the jaws at the chosen pressure. To release it, press the rings a little further and ease them apart sideways. The springy shanks then open the jaws cleanly.
Does the clamp pierce the drape?
Yes. The fine tooth on each jaw is pointed and passes through the fabric layers, and it can also take a small bite of skin. In theatre practice, tips that have passed through a sterile drape are no longer treated as sterile, so a placed clamp is not lifted and placed again on the field.
How should the towel clamp be cleaned and sterilised?
Open the ratchet and clean the jaws, joint and ratchet teeth soon after use, then rinse and dry the clamp well. Sterilise it unlocked or on the first ratchet tooth, so steam reaches every surface. The martensitic steel is made for repeated sterilisation and reuse.
Artery forceps in the surgical instruments range
More items are in the Surgical Instruments section of the Hospital Lab range.
To enquire, email [email protected] with the house code EL-SI-10953 and the quantity, or use the Add To Cart button on this page.