Bernoulli Theorem Apparatus

Bernoulli Theorem Apparatus

Product Code : EL-FML-11038

This Bernoulli Theorem Apparatus lets students check that the total head of flowing water stays nearly constant along a stream. Water circulates in a closed loop through a clear acrylic test section that narrows and then widens. Nine piezometer tubes show the pressure head at the tappings, and a 20 litre measuring tank gives the flow rate.

Specifications of the Bernoulli theorem apparatus

ComponentSpecification
Test sectionClear acrylic, narrowing and then widening, so the flow can be watched
Piezometer tubes9, PU (polyurethane) tubing
Inlet tank20 litre, stainless steel
Supply tank70 litre, stainless steel
Measuring tank20 litre, with its own piezometer tube and scale
PumpFHP (fractional horsepower), standard make
PipingGI or PVC, BSP sizes
Water circuitClosed loop from its own supply tank, so the set-up runs stand-alone
TimingElectronic stop watch
Supplied withInstallation instructions and a manual
House codeEL-FML-11038
ManufacturerLab Exports, Delhi

Experiments based on Bernoulli theorem

Bernoulli theorem applies to steady flow of an incompressible fluid along a streamline, with no losses. It says that the total head H stays constant, where H = p/(ρg) + v2/(2g) + z. Here p is the pressure, ρ the density of water, g the acceleration due to gravity, v the mean velocity at the section and z the height above a datum.

  • Verification of Bernoulli theorem. Set a steady flow and read the pressure head p/(ρg) at each tapping from its piezometer tube. Find the flow rate Q from the measuring tank, then the velocity v = Q/a at each tapping, where a is the cross-sectional area there. Add pressure head and velocity head at each point, and compare the totals at two or three flow rates.
  • Plotting the head lines. Plot pressure head, velocity head and total head against distance along the test section. The velocity head peaks at the narrowest section, where the pressure head dips. The total head line drops a little downstream because of friction losses.
  • From the theorem to flow meters. The venturi meter and orifice meter work on the same energy balance. Students next calibrate them on the Venturimeter Orificemeter Calibration Set Up, and compare flow measuring devices on the Study Of Flow Measurement Devices apparatus.

Taking a set of readings

  1. Fill the supply tank, start the pump and open the inlet valve.
  2. Let the levels in all nine piezometer tubes settle, and clear any air bubbles from the tubes and tapping lines.
  3. Read the pressure head at each tapping.
  4. Time the rise of water in the measuring tank over a set height on its scale with the electronic stop watch. Then Q = A × R/t, where A is the plan area of the tank, R the rise in level and t the time taken.
  5. Drain the measuring tank, change the inlet valve setting and repeat for two more flow rates.

Frequently Asked Questions

Why does the measured total head fall slightly along the test section?

Real water has viscosity, so friction at the walls and eddies in the widening part turn some energy into heat. Bernoulli theorem assumes no such losses, so the totals drop a little downstream. Small errors in reading the piezometer levels add to the difference.

What are the limitations of Bernoulli theorem?

It applies to steady, incompressible flow along a streamline, with no friction and no pump or turbine adding or removing energy between the two points. It does not hold across a pump or where losses are large, so the experiment uses a steady, gentle flow.

Why is the pressure head lowest at the narrowest section?

The same flow rate passes every section, so the velocity is highest where the area is smallest. The velocity head rises there, and since the total head stays nearly constant, the pressure head falls by about the same amount. It recovers as the section widens again.

What precautions give reliable readings?

Let the flow become steady and the piezometer levels settle before each set of readings. Bleed out any air bubbles, since they break the water column. Keep your eye level with the water surface to avoid parallax. Change the valve setting slowly, and time the measuring tank over a marked rise on its scale.

Does the apparatus need a hydraulic bench?

No. It is a stand-alone unit. The FHP pump circulates water in a closed loop from its own 70 litre stainless steel supply tank, and the flow is measured in its own 20 litre measuring tank. It needs water to fill the supply tank and an electrical supply for the pump.

Other apparatus for the fluid mechanics lab

More apparatus is in the Fluid Mechanics Lab section of the Engineering Lab range.

To enquire, email [email protected] with the house code EL-FML-11038 and the quantity, or use the Add To Cart button on this page. Tender buyers can also see the Tenders and OEM page.

Last updated: 19 November 2026

   

Office Address

Works:11/315, Lalita Park, Laxmi Nagar, Delhi, 110092

[email protected]

Follow Us