Electromagnet

Electromagnet

Product Code : SCL-M-11183

This electromagnet has insulated copper coils on a U-shaped soft iron core, so both poles face the same way. Run from 4-6 V DC through 4 mm binding posts, it holds a soft iron armature with a hook. Masses hung on the hook measure its holding force, and the armature drops when the current stops.

Specifications of the electromagnet

ComponentSpecification
CoreSoft iron, U-shaped, high permeability
WindingInsulated copper wire on protected bobbins
Operating voltage4-6 V DC (recommended)
Connections4 mm binding posts for banana plugs
ArmatureSoft iron keeper bar with integrated hook
Supplied withArmature with hook, instruction manual and experiment guide
House codeSCL-M-11183
ManufacturerLab Exports, Delhi

Holding-force tests with the U-core electromagnet

Current in a coil sets up a magnetic field, and a soft iron core inside the coil makes that field far stronger. Because the core is a U, the armature lies across both poles at once and closes the magnetic circuit.

  • Current against holding force. Connect a Battery Eliminator, a Rheostat Constantine (Eureka) Wire and an Ammeter in series with the coil, within the recommended 4-6 V. Fit the armature and add slotted masses on a slotted mass hanger until it falls. Repeat at several currents and plot load against current.
  • Short pulses only. Put a Tapping Key in the circuit, so that the coil is energised only by pressing it. The armature holds while the key is down and drops the moment it is released. Short pulses keep the coil cool and the current steady between readings.
  • A paper gap. Repeat one holding test with a sheet of paper between the armature and the pole faces. The load it holds falls sharply.

Add masses gently, without swinging them.

Documentation and supply

An instruction manual and experiment guide are supplied with the electromagnet. Most Lab Exports products carry a one-year manufacturer warranty.

Lab Exports manufactures the electromagnet at its works in Laxmi Nagar, Delhi, and supplies it to schools, colleges and universities in India and 60+ countries, handling the export documents for each shipment. More about the company is on the About Lab Exports page.

Frequently Asked Questions

How to measure the power of an electromagnet?

Measure its holding force, the load on the hook at which the armature pulls away. Take it at several currents, starting each time from clean pole faces. Check too that the armature falls away cleanly when the current stops.

How do I find the polarity of a U-shaped electromagnet?

Hold a compass or magnetic needle near each pole face with the current on. One face should be north and the other south. If both faces test the same, the two coils are making like poles, and the armature barely holds.

Why does the holding force stop increasing at very high currents?

The iron core saturates. Once nearly all the tiny magnetic regions in the iron are lined up, extra current adds very little to the field. The graph of load against current then levels off. On this electromagnet, stay within the recommended 4-6 V DC.

Why did the armature stay stuck even after the power was turned off?

A little magnetism stays in the iron after the current stops, and it can hold a light armature that fits closely. Soft iron keeps very little, so a gentle tap or a small load frees it.

Why is it important to place the armature flat against the core?

The field passes through iron far more easily than through air. A tilted armature leaves an air gap, so less flux crosses and the pull drops sharply. Lay the armature squarely across both pole faces for every reading.

Items for the holding-force circuit

More apparatus is in the Magnetism section of the Physics Lab range.

To enquire, email [email protected] with the house code SCL-M-11183 and the quantity, or use the Add To Cart button on this page. Tender buyers can also see the Tenders and OEM page.

Last updated: 28 November 2026

   

Office Address

Works:11/315, Lalita Park, Laxmi Nagar, Delhi, 110092

[email protected]

Follow Us